Fire Resistant Industrial Door, Fireproof Sectional Door, Fire Rated Garage Door

The Madoors USA Fire Resistant Industrial Door, Fireproof Sectional Door, and Fire Rated Garage Door range provides EI60 certified sectional fire doors for factories, warehouses, large-volume facilities, military installations, chemical facilities, and power plants — preventing fire spread between departments and across wide industrial openings where conventional fire doors cannot provide the clear opening width required for operational access. EI60 certification confirms 60-minute fire resistance with both integrity and insulation performance — maintaining the door's structural integrity and preventing the passage of heat through the door to the protected side for the full 60-minute test duration.

Available with UL and FM labels for both masonry and non-masonry applications, designed to close automatically on fire alarm activation with a time-delay release device for controlled closure, and manufactured in various sizes for different building architectures through a flexible production system, the Madoors USA fire-resistant sectional door range meets the most demanding fire safety standards alongside unusual opening sizes and discerning aesthetic requirements for commercial, industrial, institutional, and retail applications.

TECHNICAL SPECIFICATIONS
The Madoors USA Fire Resistant Industrial Sectional Door is certified to EI60 — the European fire resistance standard confirming 60-minute performance at both E (integrity — no flame, hot gases, or gap formation) and I (insulation — temperature rise on the unexposed face limited to 140°C average and 180°C maximum above ambient) criteria. EI60 certification satisfies the fire compartmentation requirements of the most demanding industrial facility fire safety regulations and insurance company risk assessment requirements for fire-rated industrial door systems.

UL and FM certification labels are available — providing American standard fire door listing for both masonry and non-masonry wall applications. UL listing satisfies the procurement requirements of US government, military, and institutional fire safety specifications. FM label provides Factory Mutual insurance and risk management organization recognition for industrial fire door applications where FM-approved products are specified by insurers as a risk reduction condition of coverage.

The door is designed to close automatically in the event of a fire or alarm activation — with a time-delay release device providing a controlled, adjustable delay between alarm activation and door closure initiation. The time-delay device provides an added measure of safety — allowing personnel to evacuate the closing door zone before the door begins its automatic closing cycle, preventing personnel from being caught by the closing door during emergency evacuation.

The flexible production system accommodates various opening sizes and different building architectures — providing fire-rated sectional door solutions for the non-standard opening dimensions frequently encountered in industrial facility construction where structural bay widths and heights do not conform to standard door catalog dimensions. This dimensional flexibility ensures that EI60 fire compartmentation can be achieved across any opening size without compromising the fire resistance performance by fitting a smaller standard door with exposed gaps.

KEY FEATURES
EI60 Certified — 60-Minute Integrity & Insulation
EI60 certification to European fire resistance standards confirms simultaneous integrity performance — no flame or hot gas passage through gaps for 60 minutes — and insulation performance — temperature rise on the protected face limited to 140°C average and 180°C maximum for 60 minutes. The combined EI classification is the most comprehensive fire door performance standard — E-only rated doors provide gap integrity but allow significant heat transfer through the door panel that can ignite materials on the protected side, while EI-rated doors prevent both gap breakthrough and radiant and conductive heat transfer.

UL & FM Labels — Masonry & Non-Masonry Applications
UL and FM certification labels provide recognized American standard fire door listing documentation for procurement specifications requiring certified fire door products. Listing for both masonry and non-masonry wall applications — concrete, masonry block, metal stud and drywall, and structural steel — allows the fire-rated sectional door to be specified for the full range of industrial building construction types without requiring separate product certifications for different wall constructions.

Automatic Closure on Fire Alarm — Time-Delay Release Device
Automatic closure on fire alarm activation ensures that the fire compartmentation function of the door is achieved without depending on operator action during an emergency — the door closes automatically when the building fire alarm system signals a fire event. The time-delay release device adds a controlled delay before closure begins — providing the personnel evacuation interval required to clear the door zone safely before the heavy sectional door begins its automated closing cycle.

Wide Opening Fire Compartmentation — Industrial Scale
The sectional door configuration specifically addresses the fire compartmentation requirement at wide industrial openings — factory vehicle access doors, warehouse bay openings, loading dock doors, and process area access openings where the clear width required for operational access significantly exceeds the standard fire door dimension. Fire compartmentation at these wide openings is a critical fire safety and insurance requirement that conventional pedestrian-scale fire doors cannot satisfy.

Flexible Size Production — Non-Standard Opening Accommodation
The flexible production system allows fire-resistant sectional doors to be manufactured in any required dimension — accommodating the non-standard opening widths and heights encountered in industrial construction without exposing fire compartmentation gaps at the perimeter of undersized standard doors. This dimensional flexibility makes Madoors USA the single-source solution for fire-rated industrial door requirements across any building architecture and any opening size combination.

Intensive Use Suitability — Industrial Performance
The fire characteristics of the door are matched by equally high performance in terms of suitability for intensive industrial use — high cycle rates, vehicle traffic, forklift contact, industrial contamination, and temperature cycling. This combination of certified fire performance and industrial operational durability is the defining quality of the Madoors USA industrial fire door range — fire performance is maintained throughout the service life of a door that is also subjected to the demanding daily operational use of an active industrial facility.

Insurance Compliance — Risk Reduction Element
Fire-resistant industrial sectional doors are increasingly demanded by insurance companies as a risk-reducing element alongside regulatory compliance — with insurance coverage and premium levels for industrial facilities directly influenced by the fire compartmentation provided by certified fire doors at internal department boundaries and external access points. Madoors USA UL and FM labeled fire doors satisfy the insurance requirement documentation for fire door certification that is increasingly required as a condition of industrial property insurance coverage.

Regulatory Compliance — Tightened Fire Safety Standards
Today's tightened fire safety regulations in industrial, commercial, and institutional facilities have expanded the application scope for certified fire-resistant sectional doors — creating regulatory requirements for fire compartmentation at industrial openings that previously had no mandatory fire door specification. Madoors USA EI60 certified sectional doors satisfy the current regulatory requirements across the full range of industrial applications — providing the certification documentation required for building permit compliance, fire safety authority approval, and insurance risk assessment.

Service Door & Counter Applications
In addition to primary fire compartmentation at wide industrial openings, fire-rated door configurations are available for service door and counter applications — providing fire-rated access doors and service counter closures for commercial, institutional, and retail projects where fire safety regulations require certified fire protection at smaller openings within the same facility.

PRODUCT RANGE
EI60 Sectional Industrial Fire Door
Wide-span EI60 certified sectional overhead door for factory, warehouse, and industrial facility fire compartmentation. Automatic closure on fire alarm, time-delay release device, UL and FM labels. Available in any required opening dimensions through flexible production system.

EI60 Fireproof Sectional Garage Door
EI60 certified sectional garage door for vehicle access points at industrial, military, chemical, and power plant facilities requiring both operational vehicle access and certified fire compartmentation. Motorized and manual operation options.

EI60 Fire Rated Garage Door — Residential & Commercial
Fire-rated sectional garage door for commercial and institutional applications — service door and counter configurations. EI60 certification for both masonry and non-masonry wall applications with UL and FM labels.

ASSEMBLY & INSTALLATION SEQUENCE
Opening Assessment & Fire Rating Specification
Opening width and height, required fire rating — EI60 standard or higher on request — wall construction type — masonry or non-masonry — UL or FM label requirement, automatic closure trigger — fire alarm interface — and time-delay release device timing are confirmed.

Structural Opening & Frame Preparation
The structural opening is prepared to the confirmed frame dimensions for the fire-rated sectional door. Frame anchor positions are designed for the masonry or non-masonry wall construction type. Fire-rated intumescent seals are specified at the frame-to-wall perimeter.

Fire-Rated Frame Installation
The fire-rated door frame is installed and anchored to the wall structure at all specified fixing positions. Fire-rated intumescent seals are installed at the frame-to-wall perimeter. Frame alignment and structural connection integrity are verified.

Sectional Panel Installation
Fire-rated sectional panels are installed on the overhead track system from the bottom section upward. Panel joint seals providing EI60 integrity at section joints are verified. Motorized drive or manual operation system is installed and connected.

Fire Alarm Interface & Automatic Closure Connection
The fire alarm system interface is connected to the door release mechanism. Time-delay release device timing is set to the specified delay period. Automatic closure test under simulated fire alarm activation is conducted and verified.

UL/FM Label Compliance Verification
All door components, installation procedures, and performance verification are reviewed for compliance with UL and FM listing requirements for the specified wall construction type. Label compliance documentation is confirmed.

Complete Fire Door System Testing & Certification Handover
Complete operational testing — automatic closure, time-delay release, manual operation, and motorized drive — is conducted. EI60 fire resistance certification, UL and FM label documentation, and installation records are compiled into the project handover package.

DEPLOYMENT SCENARIOS & USE CASES
Madoors USA Fire Resistant Industrial Doors, Fireproof Sectional Doors, and Fire Rated Garage Doors are specified for any industrial, commercial, or institutional facility opening requiring certified EI60 fire compartmentation at wide-format access points.

  • Factory and manufacturing facility fire compartment doors
  • Warehouse and distribution center fire sectional doors
  • Chemical processing facility fire-rated access doors
  • Power plant and energy facility fire compartment doors
  • Military facility fire-rated vehicle and personnel doors
  • Pharmaceutical manufacturing fire compartment doors
  • Airport terminal and ground handling facility fire doors
  • Hospital and healthcare facility fire-rated access doors
  • Data center and critical infrastructure fire-rated doors
  • Government and institutional building fire compartment doors
  • Cold storage and food processing facility fire doors
  • Automotive manufacturing facility fire compartment doors
  • Printing and paper industry fire-rated access doors
  • Mining facility fire-rated compartment doors
  • Retail and commercial facility fire-rated service doors